06000 |
WOOD
& PLASTICS |
|
|
06400-1 |
Cabinetry:
Laminate-clad base cabinets with countertop with backsplash: Install
in Lunchroom. |
6
lf |
|
06400-2 |
Rod
& Shelf in Coat Closets. |
19
lf |
|
06400-3 |
Cabinetry:
30"d. laminate-clad countertop with knee space with diagonal
supports for use as a desk. Install laminate-clad dividers on the
countertops for privacy between telephone operators. Install in Tel.
Room. |
20
lf |
|
|
|
|
08000 |
DOORS
& WINDOWS |
|
|
08000-1 |
New
Doors: 3’0"w. x 7’0"h.; solid core hardwood door with
transparent finish; hollow metal frame with lever handle and heavy
duty cylindrical latchset. |
11
dr |
|
08000-3 |
Bifold
Doors: 7’0"h. 4-panel, 1¾" solid core hardwood door
with heavy-duty bifold hardware; Painted hardwood frame to match
hollow metal frames. One 5’0"w. door and one 6’0" w.
door. |
2
dr |
|
08500-1 |
Borrow
Light: 6’0"w. x typical door height with hollow metal frame;
and ¼" tempered safety glass. Allow for wall base under the
sidelight. Install in Conf. |
1
lt |
|
|
|
|
09000 |
FINISHES |
|
|
09250-1 |
Standard
Partitions: Standard partitions to be ceiling height (stop at
underside of ceiling), with ½" gyp.bd. on each side of
3½" metal studs spaced 16" o.c.; Doors, lights, and
archways or soffits are included in length. Partitions to have
painted finish unless otherwise indicated. |
245
lf |
|
09250-2 |
Acoustical
Partitions: Same as standard partitions, but with sound attenuating
insulation inside partition. For Viewing Room & Training Room. |
54
lf |
|
09500-1 |
Acoustical
Tile Ceiling: Replace damaged tiles; clean and repair grid as
necessary; Consolidate tiles so that each space has either all new
or all old tiles. |
|
|
09500-2 |
Acoustical
Insulation: Provide a minimum 4’ width of sound attenuating
insulation above ceiling tile over partition. For Viewing Room &
Training Room. |
54
lf |
|
09680-1 |
Standard
Carpeting: Base building 26 oz. loop pile or 30 oz. cut pile nylon
carpet with direct glue-down installation and rubber base. Flooring
in the Lunchroom and File Room is existing to remain. |
4,575
sf |
|
09680-2 |
Upgraded
Carpeting: 32 oz. cut pile nylon carpet with direct glue-down
installation and rubber base. For Large Office, and Conf. Room. |
985
sf |
|
09900-1 |
Paint:
Paint partitions with painted finish that are existing to remain
with 1 coat of paint. |
530
lf |
|
|
|
|
15000 |
MECHANICAL |
|
|
15500-1 |
Acoustical
Boots: At each room with acoustical partitions, close off slots
around light fixtures, provide return air register, and provide a
boot over the return air grille. Install in Viewing Room and
Training Room. |
2
rm |
|
|
|
|
16000 |
ELECTRICAL |
|
|
16400-1 |
Electrical
Devices: Number of new duplex receptacles. Note that some outlets
require special power allowances (i.e. refrigerator, copier). |
45
dr |
|
16400-2 |
Electrical
Devices: Number of new light switches. |
18
sw |
|
16500-1 |
Light
Fixtures: Relocate 2’ x 4’ recessed parabolic fluorescent light
fixtures. Provide new fixtures to match existing if necessary. |
30
fix |
|
16500-2 |
Light
Fixtures: Adjustable recessed downlights with dimmer. Install in
Viewing Room and Training Room. |
10
fix |